ICU ventilator bppt Chinese manufacturer GYF
ICU ventilator bppt Chinese manufacturer GYF
ICU ventilator bppt Chinese manufacturer GYF
ICU ventilator bppt Chinese manufacturer GYF
ICU ventilator bppt Chinese manufacturer GYF
Price
US $9000-12000
Model
gsh100
Min. Order
1 piece

Item specifics

Type:
Respiratory equipment
Ventilation method:
auxiliary/control (A/C) manual
MV:
3~20 L/min (utilization rate 60%) 3~14L/min (u
Breathing rate:
10~60bpm
I: E ratio:
1: 2
FiO2:
60%, 100%
Trigger sensitivity:
pressure -3cmH2O
Monitoring:
pressure value: claw
Alarm:
high claws, decreased oxygen supply
Dimensions (height * width * depth):
276 * 110 * 1

Product review

Description

ICU ventilator bppt

Features

1. 5.6" TFT color screen

2.Microprocessor controlled system

3.Suitable for adult & pediatric

4.Convenient using

5.Use knob setting

6.PEEP, P-V loop, V-F loop

7.Three-level visual and audible alarm, with concise words describing problems

8.Can be used for emergency and emergency transport and ICU treatment

9.Durable and accurate built-in flow sensor

10.Integrated expiration valve, easy to be sterilized

11.Backup apnea ventilation

12.Auto nebulizer

13.Backup chargeable battery

14.Improve the breathing pattern

15.CE certified

 

Specifications

Ventilator setting

1.Patient type: Adult & Pediatric

2.Driven mode: Gas driven electronically controlled

3.Working mode: pressure limited, time cycled, volume controlled

4.Setting: Electronic Knob

5.Ventilation mode: VCV, SIGH, SIMV+VCV, CPAP, SPONT

6.Waveform: P-T, F-T, V-T, P-V Loop, V-F Loop

7.Tidal volume: 0~1500ml

8.Breathing rate: 4~100bpm

9.I:E: 3:1~1:5

10.Trigger sensitivity: -2KPa~PEEP

11.PEEP: 0~2KPa

12.Oxygen: 50~100%

  

Alarms

1.Tidal volume, Airway pressure, Respiratory rate, Apnea, Power supply failure, Lack of oxygen pressure, Battery low

2.MV: Higher limit and lower limit

3.Pressure: Higher limit and lower limit

4.V: Higher limit, lower limit

5.Rate: Higher limit, lower limit

6.Apnea: Higher limit

7.FiO: Upper limit, lower limit

8.Loudness: 5 rating: 1,2,3,4,5

 

Environment requirement

1.Power: AC110~240V, 50~60Hz

2.Gas supply: Air & Oxygen pressure: 0.28~0.6MPa, <100L/min

3.Temperature: Operation -18~50°c;    Storage -20~55°c

4.Relative humidity: Operation ≤80%, non-condensing;    Storage ≤93%, non-condensing

5.Atmospheric pressure: Operation 50~106KPa

 

Accessories

Expiratory valve

Sampling tube

Flow sensor

Control of tracheal

O pipeline

Air pipeline

Silicone tube

Test lung

 

Weight and dimension

NW: 6.6kg

GW: 7kg

Dimension: H480xW260xD420mm